Piston chart for goodman

We would like to show you a description here but the site won’t allow us.

Piston chart for goodman. The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Learn more about Goodman brand energy-efficient ARUE Series Air Handler - HVAC designed, engineered and assembled in the USA!

Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2 ... NS B1789886 FLOW CHECK PISTON KIT (M27, M28) FLOW CHECK PISTON KIT .051 (M1, M2, M3, M4, M5) NS B1789851

You are correct on the piston size, 0.78 would be HUGE. 0.078 is correct. I wondered on that, I saw that the AHRI only listed a TXV. But the piston chart that came with it lists a piston as an option. FWIW it was purchased as a system and came with both a piston and the Goodman TXV kit (Emerson TXV). I am re-using the existing lineset.Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2 ... NS B1789886 FLOW CHECK PISTON KIT (M27, M28) FLOW CHECK PISTON KIT .051 (M1, M2, M3, M4, M5) NS B1789851-40-39-38-37-36-34-33-32-31-30-29-28-27-26-24-23-22-21-20-19-18-17-16-14-13-12-11-10-9-8-7-6-4-3-2-1: 0: 1: 2: 3: 4: 6: 7: 8: 9: 10: 11: 12: 13: 14: 16: 17: 18: 19 ...required. See the Goodman piston kit chart PKC-00*. Consult your local distributor for the details regarding mix-matched orifice sizing. FILLER PLATES Filler plates are supplied on all 17.5, 21, & 24.5 inch chassis to be used for adapting the unit to a furnace one size smaller. Should the plenum and furnace openings be the same size,

NOTE: Before brazing, verify indoor piston size by checking the piston kit chart packaged with indoor unit. Leak Testing (Nitrogen or Nitrogen-Traced). To ...View and Download Goodman ARUF**14 Series installation & operating instructions manual online. ARUF**14 Series air handlers pdf manual download. ... However, in mix-matched applica- tions, a flowrator piston change may be required. See the piston kit chart (provided in the literature packet) or consult your local distributor for details ...Heating piston change (in the outdoor unit) is not required. 13. Final Charge Adjustment. All units must have refrigerant charge verified by proper adjustment of subcooling at the indoor unit after initial charge adjustment per Section 5. Proper adjustment means Goodman Gsc13 Piston Kit Chart - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Goodman Piston Kit ChartSep 19, 2020 · The physical exterior dimensions of the piston must be the same as all the others for that brand/series. Otherwise, it will not fit properly. It is only the internal bore diameter that changes. Pistons are sized in decimals of an inch, like a gas orifice, usually from the 40s to the low 100s. When a piston is described as a “65 piston,” it ...required. See the Goodman piston kit chart PKC-00*. Consult your local distributor for the details regarding mix-matched orifice sizing. FILLER PLATES Filler plates are supplied on all 17.5, 21, & 24.5 inch chassis to be used for adapting the unit to a furnace one size smaller. Should the plenum and furnace openings be the same size,

Single metal solution. The Goodman Air Handler’s All-Aluminum evaporator coil is constructed from aluminum tubing, fins and end plates giving you a single metal solution for outstanding, time-tested, heat transfer performance properties. If you’re looking for an evaporator coil that offers enhanced durability, coupled with enhanced ...piston kit chart (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested conmination indoor unit. all other indoor combinations, piston must be purchased from distruibutor. (3) txv must be purchased separately. pkcg-4001zc september 2021 too unt inoo untDetailed Description. PKC00X, PISTON KIT CHART, Goodman Parts and Accessories, Goodman HVAC Parts and Accessories. Established in 1995 by David M. Goodman, Goodman got its beginning as a small appliance store and repair shop. Soon after opening its doors to the public, David Goodman began creating a website advertising small appliances and parts. piston kit chart 2 pkcg-4001u april 2018 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately. ANZ130361A* (*) SIGNIFIES UNIT REVISION. CORRECT PISTON IS SUPPLIED WITH THE OUTDOOR UNIT. CORRECT PISTON IS SUPPLIED IN THE HIGHEST SALES VOLUME TESTED COMBINATION INDOOR UNIT. FOR ALL OTHER INDOOR COMBINATIONS, PISTON MUST BE PURCHASED FROM DISTRIBUTOR. TXV MUST BE PURCHASED SEPARATELY.

How to deposit cash into chime.

Note: Chart based on average capacity. The piston should be sized according to the capacity of the outdoor unit. Failure to install the proper piston can lead to poor system performance and possible compressor damage. 6/2015 To Change the Piston 1. The piston is located on the front panel of the coil case or in the14 SEER Piston/TXV Reference Chart Information from R410A 14 SEER AC/HP document ©2016 Ingersoll Rand Note: All match ups must be confirmed through AHRI. Condensing …15 Post Likes goodman piston size I bought some left over r22 goodman 13 seer condensor units. A gsc 2 ton and a 2 1/2 ton. Neither of these units had their …If you are looking for a reliable and energy-efficient packaged unit for your home comfort, you may want to check out the Goodman Multi-Position, Dual-Fuel, Packaged Terminal Air Conditioner (PTAC). This brochure provides you with the features, benefits, specifications and dimensions of this versatile and durable product.

GSX130361 Goodman 13 Seer Ac, 3.0 Ton R-410a 13 Seer 13 Seer 3 Ton ... Goodman Flow Check Piston Kit .070: Ships in 10 days 5.95 Add to Cart: 0121R00138PDG: Goodman Louvered Side Panel: Ships in 10 days ... but hard to find parts and accessories with detailed parts charts and pictures. Information. About; Accessibility; Careers; …AllStyle Piston Chart EFM, ELB, WLB, WFG Parts List WFM, WLB Exploded View EFM, ELB Exploded View AHBW, AHFW, AHKW Parts List AHBW, AHFW, AHKW Exploded View AHB, AHF, AHK, AHL Parts List AH Series Exploded View Coil Parts and Accessories AllStyle Parts Book Air Handler Parts By Model AH Series AllStyle Expansion Valve & …Note: For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana® outdoor unit. Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. (2) piston supplied with the indoor unit. (3) purchase piston kit from distributor. (4) b1789865 piston provided in the indoor unit. twc18-1* 18000 .052 (2) (5) piston provided in the outdoor unit liquid line service valve. twc24-1* 24000 .059 (2) 30000 .059 b1789859 (3) twcr30-1* 36000 .062 b1789862 (1) piston kit chart (cont'd) indoor unit btu'sDetailed Description. PKCG4001Q, PISTON KIT CHART, Goodman Parts and Accessories, Goodman HVAC Parts and Accessories. Established in 1995 by David M. Goodman, Goodman got its beginning as a small appliance store and repair shop. Soon after opening its doors to the public, David Goodman began creating a website advertising small appliances and ... When you purchase a Goodman air conditioner, you get the assurance that your unit is covered by a warranty. This warranty provides coverage for repair or replacement of defective parts, as well as other benefits.PISTON COILS: HEIGHT: FURNACE APPLICATION: 96-8G2(E, 9)-0P or -2P: 14" Fits all Gas and Electric ...Oct 6, 2023 · SS-DX5SE www.daikincomfort.com 3 Product Specifications DX5SEA 1810A* DX5SEA 2410A* DX5SEA 3010A* DX5SEA 3610A* DX5SEA 4210A* DX5SEA 4810A* DX5SEA 6010A*Detailed Description. PKC00X, PISTON KIT CHART, Goodman Parts and Accessories, Goodman HVAC Parts and Accessories. Established in 1995 by David M. Goodman, Goodman got its beginning as a small appliance store and repair shop. Soon after opening its doors to the public, David Goodman began creating a website advertising small …5 MULTI-POSITION (field conversion) Field Conversion Instructions from Left-to- Right or Right-to-Left Airflow Note: This applies only to models available in multi-position; Goodman GSH130361BB Pdf User Manuals. View online or download Goodman GSH130361BB Service Instructions Manual ... S-105A Piston Kit Chart for ASC13, GSC13, VSC13 ... The Goodman diagram enables the representation of the Fatigue strength of coil springs. It can be traced back to the Smith chart. This is used to calculate the fatigue strength of dynamically stressed components where the load is pulsating or alternating. In the Goodman diagram, on the other hand, only the fluctuating load is recorded.

3. Remove the check piston to verify it is correct and then replace the piston. See piston kit chart in instructions. 4. Use a tube cutter to remove the spin closure on the suc-tion line. 5. Slide the 13/16 nut into place on the tailpiece supplied in the literature bag or with the unit. 6. Braze tailpiece to the line set liquid tube. Figure 7 ...

The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Learn more about Goodman brand energy-efficient ARUE Series Air Handler - HVAC designed, engineered and assembled in the USA! 3. Remove the check piston to verify it is correct and then replace the piston. See piston kit chart in instructions. 4. Use a tube cutter to remove the spin closure on the suc-tion line. 5. Slide the 13/16 nut into place on the tailpiece supplied in the literature bag or with the unit. 6. Braze tailpiece to the line set liquid tube. Figure 7 ...The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. The CAPF Series, Upflow/Downflow Coil by Goodman is Helium Pressure-Tested - HVAC products designed, engineered and assembled in the USA!May 11, 2017 · USING THE CHARTS IN THE INSTALLATION INSTRUCTIONS, ADD OR SUBTRACT THE PROPER AMOUNT OF REFRIGERANT TO DETERMINE THE FINAL CHARGE. 3. USING A CALIBRATED SCALE, ADD OR REMOVE REFRIGERANT BASED ON YOUR CALCULATIONS . Electronic Scale . Recovery Cylinder . R-410A condensers …G: Goodman ® Brand (Standard Feature Set Model) S: Goodman ® Deluxe V: Value NOMINAL CAPACITY 018: 1.5 Tons 024: 2 Tons 030: 2.5 tons 036: 3 Tons 042: 3.5 Tons 048: 4 Tons 060: 5 tons ELECTRICAL: 1: 208-230v 1ph/60Hz 3: 208-230v 3ph/60Hz 4: 460v 3ph/60Hz MAJOR REVISION: A: Initial Release MINOR REVISION: A: Initial ReleaseFeb 12, 2006 · Thanks for the offer turtle, but according to the coil piston charts by Goodman, your range is way off. The only piston noted for any of the Goodman 2.5 ton outdoor units is the .065 piston. If you are thinking that the piston numbers noted in each of the catagories such as .058 to .065 or .078 to .065 are a range, you are reading the chart ... Slide Charts. Super Heat Calculator Subcooling Calculator Duct Sizer. Charts. Pressure Temperature Chart Orifice Chart Capillary Tube Chart Goodman Piston Coil Chart.I have a system with the dreaded Copeland rust inhibitor TXV clogging problem. I want to replace the TXV with a piston and be done with it. Are there any charts out there to size the pistons for these types of conversions? The unit is a Payne 2.5t 410a with matching evap coil. Outdoor piston size is 052.

Bank of america edd card lost.

Fighting crime cleaning up rocky mount.

piston kit chart 4 pkcg-4001u april 2018 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.piston kit chart (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested conmination indoor unit. all other indoor combinations, piston must be purchased from distruibutor. (3) txv must be purchased separately. pkcg-4001zb february 2020 ^ ] Ì e }Note: For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana® outdoor unit. Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Goodman Mfg. Co. LP. Air Conditioner User Manual. ADPF air handlers pdf manual download. Also for: Aruf, Aspf, Atuf. ... Remove the check piston to verify it is correct and then replace the piston. See piston kit chart in instructions. 4. Use a tube cutter to remove the spin closure on the suction line.Dear HVAC Forum, I just had a new condenser and evaporator installed, a Goodman model GSX130481BC 4 ton condenser and 4-5 ton Goodman model …If you’re considering purchasing a Goodman air conditioning or heating system, it’s important to understand the warranty that comes with it. A warranty provides peace of mind and ensures that you are protected against any manufacturing defe...Goodman CHPF2430B6 - Goodman 2 - 2.5 Ton, Cased/Horizontal Evaporator Coil (W 21 x D 26 x H 17.5)- The Goodman CHPF Cased Horizontal Flow Indoor Coils are made for split system air conditioners and heat pumps. The cabinet is painted Architectural Gray. This evaporator coil operates with an air conditioner or heat …Jan 10, 2014 · required. See the Goodman piston kit chart PKC-00*. Consult your local distributor for the details regarding mix-matched orifice sizing. FILLER PLATES Filler plates are supplied on all 17.5, 21, & 24.5 inch chassis to be used for adapting the unit to a furnace one size smaller. Should the plenum and furnace openings be the same size,I have a system with the dreaded Copeland rust inhibitor TXV clogging problem. I want to replace the TXV with a piston and be done with it. Are there any charts out there to size the pistons for these types of conversions? The unit is a Payne 2.5t 410a with matching evap coil. Outdoor piston size is 052. ….

Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500. Houston, Texas 77056. www.goodmanmfg.com. PKC-00Y Page 1 August 2007. f PISTON KIT CHART (cont'd) OUTDOOR INDOOR PISTON OUTDOOR INDOOR PISTON. UNIT INDOOR UNIT BTU's PISTON KIT UNIT INDOOR UNIT BTU's PISTON KIT. SIZE PART NO.Dear HVAC Forum, I just had a new condenser and evaporator installed, a Goodman model GSX130481BC 4 ton condenser and 4-5 ton Goodman model …Note: Chart based on average capacity. The piston should be sized according to the capacity of the outdoor unit. Failure to install the proper piston can lead to poor system performance and possible compressor damage. 6/2015 To Change the Piston 1. The piston is located on the front panel of the coil case or in theDetailed Description. PKC02, PISTION KIT CHART, Goodman Parts and Accessories, Goodman HVAC Parts and Accessories. Established in 1995 by David M. Goodman, Goodman got its beginning as a small appliance store and repair shop. Soon after opening its doors to the public, David Goodman began creating a website advertising small appliances and ...ANZ130361A* (*) SIGNIFIES UNIT REVISION. CORRECT PISTON IS SUPPLIED WITH THE OUTDOOR UNIT. CORRECT PISTON IS SUPPLIED IN THE HIGHEST SALES VOLUME TESTED COMBINATION INDOOR UNIT. FOR ALL OTHER INDOOR COMBINATIONS, PISTON MUST BE PURCHASED FROM DISTRIBUTOR. TXV MUST BE PURCHASED SEPARATELY. Detailed Description. PKC0AC, PISTON KIT CHART, Goodman Parts and Accessories, Goodman HVAC Parts and Accessories. Established in 1995 by David M. Goodman, Goodman got its beginning as a small appliance store and repair shop. Soon after opening its doors to the public, David Goodman began creating a website advertising small …Sizing the equipment load requires the consideration of several factors. Ceiling height, construction, window size and placement and dozens of other variables all need to be considered to properly size a heating and/or cooling system. A professionally conducted load calculation is the foundation of an effective system. Johnstone SupplyI have a system with the dreaded Copeland rust inhibitor TXV clogging problem. I want to replace the TXV with a piston and be done with it. Are there any charts out there to size the pistons for these types of conversions? The unit is a Payne 2.5t 410a with matching evap coil. Outdoor piston size is 052.Goodman 5550829 Hor Lg.case 24.5-Inch X 26-Inc 324.95 - Ships in 10 days Add to Cart; Goodman PKC-02A Pistion Kit Chart Click for details; Goodman B1755943DF Sm Md Drain Pan Ht 34.95 - Ships in 10 days Add to Cart; Goodman 5001208PDG Top Rail 24.5-Inch 5.95 - Ships in 10 days Add to Cart; Goodman 0270D00501 Tubing Assy, Evap Coil Click for ... Piston chart for goodman, , Show all. View and Download Goodman GSX technical manual online. GSX 13 SEER Series Single Phase Condensing Units with R-410A. GSX air conditioner pdf manual download. Also for: Gsx130181a, Gsx130241a, Gsx130301a, Gsx130361a, Gsx130421a, Gsx130481a, Gsx130601a, Gsx130181b, Gsx130241b,..., PISTON COILS: HEIGHT: FURNACE APPLICATION: 96-8G2(E, 9)-0P or -2P: 14" Fits all Gas and Electric ..., Detailed Description. PKC0AC, PISTON KIT CHART, Goodman Parts and Accessories, Goodman HVAC Parts and Accessories. Established in 1995 by David M. Goodman, Goodman got its beginning as a small appliance store and repair shop. Soon after opening its doors to the public, David Goodman began creating a website advertising small appliances and ... , 1. Purge gauge lines. Connect service gauge manifold to base-valve service ports. Run system at least 10 minutes to allow pressure to stabilize., piston kit chart 2 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately., Goodman GSH130361BB Pdf User Manuals. View online or download Goodman GSH130361BB Service Instructions Manual ... S-105A Piston Kit Chart for ASC13, GSC13, VSC13 ..., Packaged Units. Goodman ® is one of the biggest names in cooling, heating and energy-efficient home comfort. That’s because Goodman lives up to its name in a big way, with time-tested energy-efficient technology, highly-durable materials and spot-on manufacturing. So, no matter where you live or whether your home is small or large, Goodman ..., 3 To avoid possible explosion, use only returnable (not disposable) service cylinders when removing refrigerant from a system. • Ensure the cylinder is free of damage which could lead to, piston kit chart outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) 24000 .059 to .052 b17898-52 (3) 42000 .078 to .073 b17898-73 (1) 29000 .059 to .052 b17898-52 (3) 47000 .082 to .073 ... , Sizing the equipment load requires the consideration of several factors. Ceiling height, construction, window size and placement and dozens of other variables all need to be considered to properly size a heating and/or cooling system. A professionally conducted load calculation is the foundation of an effective system., Temp. Temp. Temp. Temp. Temp. Temp. Temp. Temp. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C)-49 5.5 5.4 -45.0 1 49.7 49.5 -17.2 51 145.8 145.2 10.6 101 323.1 322.1 38.3-48 6.0 5.9 -44.4 2 51.1 50.8 -16.7 52 148.4 147.9 11.1 102 327.7 326.7 38.9, Detailed Description. PKC02, PISTION KIT CHART, Goodman Parts and Accessories, Goodman HVAC Parts and Accessories. Established in 1995 by David M. Goodman, Goodman got its beginning as a small appliance store and repair shop. Soon after opening its doors to the public, David Goodman began creating a website advertising small appliances and ..., ModelGSX13. TypeSplit Air Conditioner. Cooling Capacity BTU 19000 Btu/H. Efficiency 13 SEER. Compressor Single Stage. Energy Certified No. Liquid Line Connection Size 3/8 in. SuctionLine 3/4 in. Maximum - Voltage 253 V., ANZ130361A* (*) SIGNIFIES UNIT REVISION. CORRECT PISTON IS SUPPLIED WITH THE OUTDOOR UNIT. CORRECT PISTON IS SUPPLIED IN THE HIGHEST SALES VOLUME TESTED COMBINATION INDOOR UNIT. FOR ALL OTHER INDOOR COMBINATIONS, PISTON MUST BE PURCHASED FROM DISTRIBUTOR. TXV MUST BE PURCHASED SEPARATELY. , In “Young Goodman Brown,” Nathaniel Hawthorne writes about the dangers of basing a society on strict religious and moral values. Other themes include the loss of innocence and why some men choose to give in to evil., The duration of warranty coverage in Texas and Florida differs in some cases. Product Brochure View All Documents. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Find a Dealer. Learn more about the refreshingly affordable Goodman GSZ14 Heat Pump with up to 15 SEER / 9.0 HSPF …, Goodman Gsc13 Piston Kit Chart - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Goodman Piston Kit Chart, Aug 3, 2023 · 5 MULTI-POSITION (field conversion) Field Conversion Instructions from Left-to- Right or Right-to-Left Airflow Note: This applies only to models available in multi-position; see Specification Guide for details; typical horizontal left-to- right conversion is shown., View and Download Goodman GSH Series service instructions manual online. Split System Air Conditioners, Split System Heat Pumps with R-22 Refrigerant Blowers, Coils, & Accessories. ... (noisy opera- S-105A PISTON KIT CHART FOR ASC13, tion) for 1 or 2 seconds at shutdown. This is normal and GSC13, VSC13, GSC14, ASH13, GSH13, does …, Goodman Thermostat Installation and Commissioning. Goodman GTST thermostat Homeowner App Settings for Unitary. Goodman GTST thermostat Local Thermostat Settings for Unitary. The Goodman literature library has consumer brochures and technical specifications for various Goodman HVAC models and product lines., Buy it with. This item: Goodman-Amana B1789880 Flow Check Piston Kit .080. $1504. +. OEM Upgraded Replacement for Goodman Furnace Vent Air Pressure Switch B13701-42. $1390. +. Upgraded Replacement 0130F00010 fits Goodman Furnace Flame Sensor B11726-06 (3 Pack) $799., In other words, a higher superheat means a lower percentage of the coil is being fed with saturated (boiling) refrigerant. The higher the % of the coil being fed, the higher the capacity of the system and the higher the efficiency of the coil. This is why we often “set the charge” using superheat once all other parameters are properly set ..., How to remove and replace a flow rater piston. What you need to know to do correctly. Thanks for watching!- [email protected] me on Facebook:..., (4) b17898-65 piston provided on indoor coil ae(r)60 .090 (2) (5) correct piston already ..., Temp. Temp. Temp. Temp. Temp. Temp. Temp. Temp. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C)-49 5.5 5.4 -45.0 1 49.7 49.5 -17.2 51 145.8 145.2 10.6 101 323.1 322.1 38.3-48 6.0 5.9 -44.4 2 51.1 50.8 -16.7 52 148.4 147.9 11.1 102 327.7 326.7 38.9, Feb 11, 2006 · Thanks for the offer turtle, but according to the coil piston charts by Goodman, your range is way off. The only piston noted for any of the Goodman 2.5 ton outdoor units is the .065 piston. If you are thinking that the piston numbers noted in each of the catagories such as .058 to .065 or .078 to .065 are a range, you are reading the chart …, 15 Post Likes goodman piston size I bought some left over r22 goodman 13 seer condensor units. A gsc 2 ton and a 2 1/2 ton. Neither of these units had their customary piston connected to the condenser under the electrical panal. I decided to look online and get the piston size but under piston size for these 2 units just have a slash., I have a system with the dreaded Copeland rust inhibitor TXV clogging problem. I want to replace the TXV with a piston and be done with it. Are there any charts out there to size the pistons for these types of conversions? The unit is a Payne 2.5t 410a with matching evap coil. Outdoor piston size is 052., goodman manufacturing company,l.p. drawing to be interpreted in accordance with asme y14.100 title dimensions are in inches wrapper, small unless otherwise noted. tolerances unless otherwise noted angles 1.5.x .1.xx .03.xxx .015 holes : .005 tube cut lg: .063 dwn: bf eng: scale: nts date: 11-01-99 chk: sjk sheet: 2 of 3 dwg. no. 3702004 f2, May 11, 2017 · USING THE CHARTS IN THE INSTALLATION INSTRUCTIONS, ADD OR SUBTRACT THE PROPER AMOUNT OF REFRIGERANT TO DETERMINE THE FINAL CHARGE. 3. USING A CALIBRATED SCALE, ADD OR REMOVE REFRIGERANT BASED ON YOUR CALCULATIONS . Electronic Scale . Recovery Cylinder . R-410A condensers …, G Goodman® Brand Major & Minor Revisions (not used for inventory or ordering) Product Category Electrical S Split System 1 208/230 V, 1 Phase, 60 Hz 2 220/240 V, 1 Phase, 50 Hz Unit Type 3 208/230 V, 3 Phase, 60 Hz X Condenser R-­‐410A Z Heat Pump R-­‐410A Nominal Capacity 018, Air Conditioner Carrier 38CKC Product Data. 60 hz air conditioner sizes 018 thru 060 (29 pages) Air Conditioner Carrier 38CKC Installation And Start-Up Instructions Manual. Carrier 10 seer split system air conditioner (13 pages) Air Conditioner Carrier 38CKG Installation And Start-Up Instructions Manual. 10 seer split system (12 pages) Air ...